Logo
  • Home
  • About Us
    • Aim and Scope
    • Research Area
    • Impact Factor
    • Indexing
  • For Authors
    • Authors Guidelines
    • How to publish paper?
    • Download Paper format
    • Submit Manuscript
    • Processing Charges
    • Download Copyrights Form
    • Submit Payment-Copyrights
  • Archives
    • Current Issues
    • Past Issues
    • Conference Issues
    • Special Issues
    • Advance Search
  • IJARIIE Board
    • Join as IJARIIE Board
    • Advisory Board
    • Editorial Board
    • Sr. Reviewer Board
    • Jr. Reviewer Board
  • Proposal
    • Conferece Proposal
    • Special Proposal
    • Faqs
  • Contact Us
  • Payment Detail

Call for Papers:Vol.11 Issue.3

Submission
Last date
28-Jun-2025
Acceptance Status In One Day
Paper Publish In Two Days
Submit ManuScript

News & Updates

Submit Article

Dear Authors, Article publish in our journal for Volume-11,Issue-3. For article submission on below link: Submit Manuscript


Join As Board

Dear Reviewer, You can join our Reviewer team without given any charges in our journal. Submit Details on below link: Join As Board


Paper Publication Charges

IJARIIE APP
Download Android App

For Authors

  • How to Publish Paper
  • Submit Manuscript
  • Processing Charges
  • Submit Payment

Archives

  • Current Issue
  • Past Issue

IJARIIE Board

  • Member Of Board
  • Join As Board

Downloads

  • Authors Guidelines
  • Manuscript Template
  • Copyrights Form

Android App

Download IJARIIE APP
  • Authors
  • Abstract
  • Citations
  • Downloads
  • Similar-Paper

Authors

Title: :  ANALYZING THE CONSISTENCY OF BEAM QUALITY AND OUTPUT DOSE/MU FOR PHOTON BEAMS OF ENERGY 6 MV AND 15 MV OF A MEDICAL LINAC USED FOR RADIOTHERAPY AT INSTITUTE OF NUCLEAR MEDICAL PHYSICS, AERE, SAVAR.
PaperId: :  18268
Published in:   International Journal Of Advance Research And Innovative Ideas In Education
Publisher:   IJARIIE
e-ISSN:   2395-4396
Volume/Issue:    Volume 8 Issue 5 2022
DUI:    16.0415/IJARIIE-18268
Licence: :   IJARIIE is licensed under a Creative Commons Attribution-ShareAlike 4.0 International License.

Author NameAuthor Institute
M.A. HasnatInstitute of Nuclear Medical Physics
K.M.M. MorshedInstitute of Nuclear Science and Technology
M.M. ParvejInstitute of Nuclear Medical Physics
M.S. SultanaInstitute of Nuclear Medical Physics
Juwel HosenInstitute of Nuclear Medical Physics
M.M. AhasanInstitute of Nuclear Medical Physics
Shirin AkterDepartment of Health Physics, Atomic Energy Centre
A.N. MonikaDepartment of Health Physics, Atomic Energy Centre

Abstract

Radio Therapy, Medical Physics
Dosimetry, Consistency, Beam Quality, Output Dose
Medical Linac (linear accelerator) delivers ionizing radiation which is used for cancer management. In radiotherapy, it is mandatory to provide maximum dose to the cancerous tumor and minimum dose to the surrounding normal tissues. So it is required to assess the consistency of beam quality and beam output dose/MU (Monitor Unit). The output dose of Linac (Model: CLINAC-iX) of photon beam of energy 6 MV and 15 MV installed at Institute of Nuclear Medical Physics, AERE Savar has been measured with FC65-P ionization chamber using 1D Water Phantom. In this study, data collection period was from October 2019 to September 2022 in accordance with the TRS-398 dosimetry protocols. Over the period of 36 months we found that TPR20,10 for 6 MV photon beam was 0.67 corresponding and TPR20,10 for 15 MV photon was 0.76. Which showed that the values of beam quality TPR20,10 never changed when the values are rounded to two decimal points. The measured output dose/MU was found in between 0.998 to 1.023 cGy for 6MV photon and 0.998 to 1.032 cGy for 15MV photon. The dose/MU for all radiation beams was maintained within 2% of deviation from the recommended value 1cGy/MU at Dmax position over the period of 36 months. In our study, the observed deviations of output dose/MU were maintained in tolerance interval instructed by the protocol. If the tolerance crossed the machine tuned of the monitor unit for getting 1 cGy/MU at the Dmax position in water. Here, absorbed dose to water based protocol was followed which reduced the uncertainty of the accuracy of the dose determination.

Citations

Copy and paste a formatted citation or use one of the links to import into a bibliography manager and reference.

IJARIIE M.A. Hasnat, K.M.M. Morshed, M.M. Parvej, M.S. Sultana, Juwel Hosen, M.M. Ahasan, Shirin Akter, and A.N. Monika. "ANALYZING THE CONSISTENCY OF BEAM QUALITY AND OUTPUT DOSE/MU FOR PHOTON BEAMS OF ENERGY 6 MV AND 15 MV OF A MEDICAL LINAC USED FOR RADIOTHERAPY AT INSTITUTE OF NUCLEAR MEDICAL PHYSICS, AERE, SAVAR." International Journal Of Advance Research And Innovative Ideas In Education Volume 8 Issue 5 2022 Page 898-903
MLA M.A. Hasnat, K.M.M. Morshed, M.M. Parvej, M.S. Sultana, Juwel Hosen, M.M. Ahasan, Shirin Akter, and A.N. Monika. "ANALYZING THE CONSISTENCY OF BEAM QUALITY AND OUTPUT DOSE/MU FOR PHOTON BEAMS OF ENERGY 6 MV AND 15 MV OF A MEDICAL LINAC USED FOR RADIOTHERAPY AT INSTITUTE OF NUCLEAR MEDICAL PHYSICS, AERE, SAVAR.." International Journal Of Advance Research And Innovative Ideas In Education 8.5(2022) : 898-903.
APA M.A. Hasnat, K.M.M. Morshed, M.M. Parvej, M.S. Sultana, Juwel Hosen, M.M. Ahasan, Shirin Akter, & A.N. Monika. (2022). ANALYZING THE CONSISTENCY OF BEAM QUALITY AND OUTPUT DOSE/MU FOR PHOTON BEAMS OF ENERGY 6 MV AND 15 MV OF A MEDICAL LINAC USED FOR RADIOTHERAPY AT INSTITUTE OF NUCLEAR MEDICAL PHYSICS, AERE, SAVAR.. International Journal Of Advance Research And Innovative Ideas In Education, 8(5), 898-903.
Chicago M.A. Hasnat, K.M.M. Morshed, M.M. Parvej, M.S. Sultana, Juwel Hosen, M.M. Ahasan, Shirin Akter, and A.N. Monika. "ANALYZING THE CONSISTENCY OF BEAM QUALITY AND OUTPUT DOSE/MU FOR PHOTON BEAMS OF ENERGY 6 MV AND 15 MV OF A MEDICAL LINAC USED FOR RADIOTHERAPY AT INSTITUTE OF NUCLEAR MEDICAL PHYSICS, AERE, SAVAR.." International Journal Of Advance Research And Innovative Ideas In Education 8, no. 5 (2022) : 898-903.
Oxford M.A. Hasnat, K.M.M. Morshed, M.M. Parvej, M.S. Sultana, Juwel Hosen, M.M. Ahasan, Shirin Akter, and A.N. Monika. 'ANALYZING THE CONSISTENCY OF BEAM QUALITY AND OUTPUT DOSE/MU FOR PHOTON BEAMS OF ENERGY 6 MV AND 15 MV OF A MEDICAL LINAC USED FOR RADIOTHERAPY AT INSTITUTE OF NUCLEAR MEDICAL PHYSICS, AERE, SAVAR.', International Journal Of Advance Research And Innovative Ideas In Education, vol. 8, no. 5, 2022, p. 898-903. Available from IJARIIE, https://ijariie.com/AdminUploadPdf/ANALYZING_THE_CONSISTENCY_OF_BEAM_QUALITY_AND_OUTPUT_DOSE_MU_FOR_PHOTON_BEAMS_OF_ENERGY_6_MV_AND_15_MV_OF_A_MEDICAL_LINAC_USED_FOR_RADIOTHERAPY_AT_INSTITUTE_OF_NUCLEAR_MEDICAL_PHYSICS__AERE__SAVAR__ijariie18268.pdf (Accessed : 15 October 2022).
Harvard M.A. Hasnat, K.M.M. Morshed, M.M. Parvej, M.S. Sultana, Juwel Hosen, M.M. Ahasan, Shirin Akter, and A.N. Monika. (2022) 'ANALYZING THE CONSISTENCY OF BEAM QUALITY AND OUTPUT DOSE/MU FOR PHOTON BEAMS OF ENERGY 6 MV AND 15 MV OF A MEDICAL LINAC USED FOR RADIOTHERAPY AT INSTITUTE OF NUCLEAR MEDICAL PHYSICS, AERE, SAVAR.', International Journal Of Advance Research And Innovative Ideas In Education, 8(5), pp. 898-903IJARIIE [Online]. Available at: https://ijariie.com/AdminUploadPdf/ANALYZING_THE_CONSISTENCY_OF_BEAM_QUALITY_AND_OUTPUT_DOSE_MU_FOR_PHOTON_BEAMS_OF_ENERGY_6_MV_AND_15_MV_OF_A_MEDICAL_LINAC_USED_FOR_RADIOTHERAPY_AT_INSTITUTE_OF_NUCLEAR_MEDICAL_PHYSICS__AERE__SAVAR__ijariie18268.pdf (Accessed : 15 October 2022)
IEEE M.A. Hasnat, K.M.M. Morshed, M.M. Parvej, M.S. Sultana, Juwel Hosen, M.M. Ahasan, Shirin Akter, and A.N. Monika, "ANALYZING THE CONSISTENCY OF BEAM QUALITY AND OUTPUT DOSE/MU FOR PHOTON BEAMS OF ENERGY 6 MV AND 15 MV OF A MEDICAL LINAC USED FOR RADIOTHERAPY AT INSTITUTE OF NUCLEAR MEDICAL PHYSICS, AERE, SAVAR.," International Journal Of Advance Research And Innovative Ideas In Education, vol. 8, no. 5, pp. 898-903, Sep-Oct 2022. [Online]. Available: https://ijariie.com/AdminUploadPdf/ANALYZING_THE_CONSISTENCY_OF_BEAM_QUALITY_AND_OUTPUT_DOSE_MU_FOR_PHOTON_BEAMS_OF_ENERGY_6_MV_AND_15_MV_OF_A_MEDICAL_LINAC_USED_FOR_RADIOTHERAPY_AT_INSTITUTE_OF_NUCLEAR_MEDICAL_PHYSICS__AERE__SAVAR__ijariie18268.pdf [Accessed : 15 October 2022].
Turabian M.A. Hasnat, K.M.M. Morshed, M.M. Parvej, M.S. Sultana, Juwel Hosen, M.M. Ahasan, Shirin Akter, and A.N. Monika. "ANALYZING THE CONSISTENCY OF BEAM QUALITY AND OUTPUT DOSE/MU FOR PHOTON BEAMS OF ENERGY 6 MV AND 15 MV OF A MEDICAL LINAC USED FOR RADIOTHERAPY AT INSTITUTE OF NUCLEAR MEDICAL PHYSICS, AERE, SAVAR.." International Journal Of Advance Research And Innovative Ideas In Education [Online]. volume 8 number 5 (15 October 2022).
Vancouver M.A. Hasnat, K.M.M. Morshed, M.M. Parvej, M.S. Sultana, Juwel Hosen, M.M. Ahasan, Shirin Akter, and A.N. Monika. ANALYZING THE CONSISTENCY OF BEAM QUALITY AND OUTPUT DOSE/MU FOR PHOTON BEAMS OF ENERGY 6 MV AND 15 MV OF A MEDICAL LINAC USED FOR RADIOTHERAPY AT INSTITUTE OF NUCLEAR MEDICAL PHYSICS, AERE, SAVAR.. International Journal Of Advance Research And Innovative Ideas In Education [Internet]. 2022 [Cited : 15 October 2022]; 8(5) : 898-903. Available from: https://ijariie.com/AdminUploadPdf/ANALYZING_THE_CONSISTENCY_OF_BEAM_QUALITY_AND_OUTPUT_DOSE_MU_FOR_PHOTON_BEAMS_OF_ENERGY_6_MV_AND_15_MV_OF_A_MEDICAL_LINAC_USED_FOR_RADIOTHERAPY_AT_INSTITUTE_OF_NUCLEAR_MEDICAL_PHYSICS__AERE__SAVAR__ijariie18268.pdf
BibTex EndNote RefMan RefWorks

Number Of Downloads


Last download on 10/15/2022 7:31:19 PM

Save in Google Drive

Similar-Paper

TitleArea of ResearchAuther NameAction
Emerging Trends in Renewable Energy: Innovations and Future Directions for Solar, Wind, and Geothermal PowerPhysicsEnass Milud Shaban Algammudi Download
Global Renewable Energy Utilization: A Five-Year Review (2019-2024)Renewable EnergyB. M. Pehere Download
THE FUTURE OF SPACE EXPLORATION: PHYSICS CHALLENGES AHEADPhysics SUNEET SINGH Download
Revolutionizing Technology: Exploring The Applications of Quantum Physics In Computing, Communication, And Advanced MaterialsPhysicsKammili Sirisha Download
Review On Natural Hybrid Composite MaterialsEngineeringNithin M Download
Preparation, characterization and antimicrobial potential of essential oil based nano emulsion formulated with Saponin extractBio PhysicsMiss. Jaya Nalawade Download
EXPLORING THE RECENT ADVANCEMENT OF HIGH TEMPERATURE SUPERCONDUCTORSScienceS V Sharma Download
ASTRAL PROJECTIONPhysicsJ. P. Pramod Download
Exploring the Applications of High Temperature Superconductors in Modern TechnologiesScienceS V Sharma Download
Methodology to Size a Hybrid Energy Systems for Remote Regions: Technical-economic Analysis, Minimizing LCoE and CO2 EmissionsSciences and TechnologiesF. Philibert ANDRINIRINIAIMALAZA Download
Automated unsupervised recognition of cone photoreceptor cells in adaptive optics scanning laser ophthalmoscope imagesPhysicsRakesh Download
FLUID MECHANICS IN ACTION: THE FUTURE OF THAI BRIDGES WITH HYDRAULIC TECHNOLOGYCivil EngineeringAmie G. Jara Download
THE HIGGS BOSON DISCOVERY: IMPLICATIONS FOR PARTICLE PHYSICSPhysics Sahil Kumar Download
GRAVITATIONAL WAVES: OBSERVATIONAL EVIDENCE AND IMPLICATIONS FOR ASTROPHYSICSPhysics Sahil Kumar Download
BLACK HOLE THERMODYNAMICS: INSIGHTS FROM STRING THEORYPhysics SAHIL KUMAR Download
12
For Authors
  • Submit Paper
  • Processing Charges
  • Submit Payment
Archive
  • Current Issue
  • Past Issue
IJARIIE Board
  • Member Of Board
  • Join As Board
Privacy and Policy
Follow us

Contact Info
  • +91-8401209201 (India)
  • +86-15636082010 (China)
  • ijariiejournal@gmail.com
  • M-20/234 Ami Appt,
    Nr.Naranpura Tele-Exch,
    Naranpura,
    Ahemdabad-380063
    Gujarat,India.
Copyright © 2025. IJARIIE. All Rights Reserved.