CURRENT CONTROL ANALYSIS USING A PROPORTIONAL RESONANT (PR) CONTROLLER IN A SINGLE-PHASE GRID-CONNECTED INVERTER SYSTEM

September 2026
Vol-12, Issue-5
Paper ID: 28937
ISSN: 2395-4396
Downloads: 91
Download PDF

Abstract & Details

Research Area
ELECTRICAL ENGINEERING
Keywords
Current Control Proportional Resonant Controller Single-Phase Inverter Grid-Connected Inverter Power Electronics
Abstract
This study analyzes the performance of a Proportional Resonant (PR) controller for current control in a single-phase grid-connected inverter. The system uses an LCL filter to reduce current harmonics and improve power quality. The inverter is simulated using MATLAB/Simulink with a 400 V DC input, 220 V RMS AC output, and 50 Hz grid frequency. The performance is evaluated based on current tracking, steady-state error, and harmonic distortion. The results are expected to demonstrate the effectiveness of the PR controller in accurately tracking the sinusoidal current reference and improving the quality of grid-connected current.

Author Information

# Name Institute / Affiliation
1 Cynthia Fitriana Dewi UNIVERSITAS DIPONEGORO SEMARANG

How to Cite

Use the following formats to cite this article in your research.

APA Style
Dewi, Cynthia Fitriana (2026). CURRENT CONTROL ANALYSIS USING A PROPORTIONAL RESONANT (PR) CONTROLLER IN A SINGLE-PHASE GRID-CONNECTED INVERTER SYSTEM. International Journal of Advance Research and Innovative Ideas In Education, 12(5), 363-374.
MLA Style
Dewi, Cynthia Fitriana. "CURRENT CONTROL ANALYSIS USING A PROPORTIONAL RESONANT (PR) CONTROLLER IN A SINGLE-PHASE GRID-CONNECTED INVERTER SYSTEM." International Journal of Advance Research and Innovative Ideas In Education, vol. 12, no. 5, 2026, pp. 363-374.
IEEE Style
Cynthia Fitriana Dewi, "CURRENT CONTROL ANALYSIS USING A PROPORTIONAL RESONANT (PR) CONTROLLER IN A SINGLE-PHASE GRID-CONNECTED INVERTER SYSTEM," International Journal of Advance Research and Innovative Ideas In Education, vol. 12, no. 5, pp. 363-374, 2026.
Vancouver Style
Dewi Cynthia Fitriana. CURRENT CONTROL ANALYSIS USING A PROPORTIONAL RESONANT (PR) CONTROLLER IN A SINGLE-PHASE GRID-CONNECTED INVERTER SYSTEM. International Journal of Advance Research and Innovative Ideas In Education. 2026;12(5):363-374.
Harvard Style
Dewi, Cynthia Fitriana (2026) 'CURRENT CONTROL ANALYSIS USING A PROPORTIONAL RESONANT (PR) CONTROLLER IN A SINGLE-PHASE GRID-CONNECTED INVERTER SYSTEM', International Journal of Advance Research and Innovative Ideas In Education, 12(5), pp. 363-374.
Chicago Style
Dewi, Cynthia Fitriana. "CURRENT CONTROL ANALYSIS USING A PROPORTIONAL RESONANT (PR) CONTROLLER IN A SINGLE-PHASE GRID-CONNECTED INVERTER SYSTEM." International Journal of Advance Research and Innovative Ideas In Education 12, no. 5 (2026): 363-374.
Turabian Style
Dewi, Cynthia Fitriana. "CURRENT CONTROL ANALYSIS USING A PROPORTIONAL RESONANT (PR) CONTROLLER IN A SINGLE-PHASE GRID-CONNECTED INVERTER SYSTEM." International Journal of Advance Research and Innovative Ideas In Education 12, no. 5 (2026): 363-374.

Export Citation