"Comparative study of Conventional Tray and Advanced Tray in tray drying"

April 2017
Vol-3, Issue-2
Paper ID: 4563
ISSN: 2395-4396
Downloads: 93
Download PDF

Abstract & Details

Research Area
Chemical Engineering
Keywords
Tray Dryer Flat Plate Porous Plate Cross-Flow Through Circulation Rate of Drying Energy saving in dryer Batch Dryer
Abstract
This paper compares performance of conventional tray and advanced tray (i.e., Porous tray) used in Batch dryer, in terms of drying time. The flat plate was used as conventional tray with Hexamine powder as test material and the porous tray was considered as advanced tray with similar Hexamine powder as test material, for drying. The drying was carried out with equal material in each plate spread uniformly until material was bone dry for both types of plates and results were noted. The result of drying curve show that for constant rate period, the rate of drying of advanced tray is greater than that for flat plate (1.45 times); And for falling rate period the curve is steeper for Flat plate. However, in case of porous tray the constant rate period is up to greater extent of drying (0.03gm/gm) than for flat plate (0.04 gm/gm). This is reflected as greater span of the constant rate period for the porous tray curve than for the flat plate curve. The observation concludes that the total drying time is 2.26 times for porous tray than for flat plate. Thus, porous tray shows increased rate of drying with less energy consumption.

Author Information

# Name Institute / Affiliation
1 Ramchandani Hitesh R. L.D College of Engineering
2 Parmar Durgesh N. L.D College of Engineering
3 Desai Manoj G. L.D College of Engineering

How to Cite

Use the following formats to cite this article in your research.

APA Style
R., Ramchandani Hitesh, N., Parmar Durgesh, & G., Desai Manoj (2017). "Comparative study of Conventional Tray and Advanced Tray in tray drying". International Journal of Advance Research and Innovative Ideas In Education, 3(2), 3051-3059.
MLA Style
R., Ramchandani Hitesh, et al. ""Comparative study of Conventional Tray and Advanced Tray in tray drying"." International Journal of Advance Research and Innovative Ideas In Education, vol. 3, no. 2, 2017, pp. 3051-3059.
IEEE Style
Ramchandani Hitesh R., Parmar Durgesh N., and Desai Manoj G., ""Comparative study of Conventional Tray and Advanced Tray in tray drying"," International Journal of Advance Research and Innovative Ideas In Education, vol. 3, no. 2, pp. 3051-3059, 2017.
Vancouver Style
R. Ramchandani Hitesh, N. Parmar Durgesh, G. Desai Manoj. "Comparative study of Conventional Tray and Advanced Tray in tray drying". International Journal of Advance Research and Innovative Ideas In Education. 2017;3(2):3051-3059.
Harvard Style
R., Ramchandani Hitesh, N., Parmar Durgesh, & G., Desai Manoj (2017) '"Comparative study of Conventional Tray and Advanced Tray in tray drying"', International Journal of Advance Research and Innovative Ideas In Education, 3(2), pp. 3051-3059.
Chicago Style
R., Ramchandani Hitesh, Parmar Durgesh N., and Desai Manoj G.. ""Comparative study of Conventional Tray and Advanced Tray in tray drying"." International Journal of Advance Research and Innovative Ideas In Education 3, no. 2 (2017): 3051-3059.
Turabian Style
R., Ramchandani Hitesh, Parmar Durgesh N., and Desai Manoj G.. ""Comparative study of Conventional Tray and Advanced Tray in tray drying"." International Journal of Advance Research and Innovative Ideas In Education 3, no. 2 (2017): 3051-3059.

Export Citation

Related Research

Hydrogel nanoparticle for removal of heavy metals (Zinc)
Prof. Mr.Divate Sachin et al. 2025 Chemical Engineering
Download PDF