Logo
  • Home
  • About Us
    • Aim and Scope
    • Research Area
    • Impact Factor
    • Indexing
  • For Authors
    • Authors Guidelines
    • How to publish paper?
    • Download Paper format
    • Submit Manuscript
    • Processing Charges
    • Download Copyrights Form
    • Submit Payment-Copyrights
  • Archives
    • Current Issues
    • Past Issues
    • Conference Issues
    • Special Issues
    • Advance Search
  • IJARIIE Board
    • Join as IJARIIE Board
    • Advisory Board
    • Editorial Board
    • Sr. Reviewer Board
    • Jr. Reviewer Board
  • Proposal
    • Conferece Proposal
    • Special Proposal
    • Faqs
  • Contact Us
  • Payment Detail

Call for Papers:Vol.11 Issue.3

Submission
Last date
28-Jun-2025
Acceptance Status In One Day
Paper Publish In Two Days
Submit ManuScript

News & Updates

Submit Article

Dear Authors, Article publish in our journal for Volume-11,Issue-3. For article submission on below link: Submit Manuscript


Join As Board

Dear Reviewer, You can join our Reviewer team without given any charges in our journal. Submit Details on below link: Join As Board


Paper Publication Charges

IJARIIE APP
Download Android App

For Authors

  • How to Publish Paper
  • Submit Manuscript
  • Processing Charges
  • Submit Payment

Archives

  • Current Issue
  • Past Issue

IJARIIE Board

  • Member Of Board
  • Join As Board

Downloads

  • Authors Guidelines
  • Manuscript Template
  • Copyrights Form

Android App

Download IJARIIE APP
  • Authors
  • Abstract
  • Citations
  • Downloads
  • Similar-Paper

Authors

Title: :  Identification of transformer internal faults by conventional and fuzzy three gas ratio method
PaperId: :  1779
Published in:   International Journal Of Advance Research And Innovative Ideas In Education
Publisher:   IJARIIE
e-ISSN:   2395-4396
Volume/Issue:    Volume 2 Issue 2 2016
DUI:    16.0415/IJARIIE-1779
Licence: :   IJARIIE is licensed under a Creative Commons Attribution-ShareAlike 4.0 International License.

Author NameAuthor Institute
Vaishali B. MoreAmrutvahini college of engg. sangamner
Pooja P.KoshtiAmrutvahini college of engg. sangamner
Shweta B. kuteAmrutvahini college of engg. sangamner
Kavita B. ArgadeAmrutvahini college of engg. sangamner

Abstract

Electrical engineering
acetylene (C2H2) , carbon monoxide (CO), carbon dioxide (CO2), Dissolved gas analysis (DGA),ethylene (C2H4), ethane (C2H6),Key gases, hydrogen (H2), methane (CH4)
Transformer is a main device of power system on which cost of electricity supply depends. Hence, to manage the life of transformers, to reduce failures and to extend the life of transformer, some preventive measures are being adopted. Power system reliability depends on the consistency of electrical equipment. DGA is most useful technique for fault detection in oil insulated transformer. Dissolved Gas Analysis (DGA) is the heart of on-line monitoring as it is a well-established method of transformer diagnosis. DGA techniques are simple, inexpensive, and widely used to interpret gases dissolved due to the deterioration of the insulating oil of power transformers and hence to diagnosis, possibility of various type of faults in power transformer. Different methods for detection are key gas method, ratio method. When more than one fault exists in a transformer, these methods sometimes fail to diagnose. IEC Three Ratio Method is widely used, but in many cases this method cannot accurately diagnose (such as no matching, multiple faults).This paper proposes the fuzzy three ratio method which overcomes the drawbacks of the conventional three-ratio method this paper first propose the fuzzy membership functions for codes "zero", "one", "two", then it transfer the conventional logic "AND" and "OR" used in IEC three-ratio method into fuzzy logic. Simulation proves the proposed method can overcome the drawbacks of the conventional three-ratio method that cannot diagnose multi-fault and no matching codes for diagnosis, thus, it greatly enhanced diagnosing accuracy. Also this paper present three fault type, partial discharges (PD), arc discharges, and thermal faults, Winding circulate current.

Citations

Copy and paste a formatted citation or use one of the links to import into a bibliography manager and reference.

IJARIIE Vaishali B. More, Pooja P.Koshti, Shweta B. kute, and Kavita B. Argade. "Identification of transformer internal faults by conventional and fuzzy three gas ratio method" International Journal Of Advance Research And Innovative Ideas In Education Volume 2 Issue 2 2016 Page 724-730
MLA Vaishali B. More, Pooja P.Koshti, Shweta B. kute, and Kavita B. Argade. "Identification of transformer internal faults by conventional and fuzzy three gas ratio method." International Journal Of Advance Research And Innovative Ideas In Education 2.2(2016) : 724-730.
APA Vaishali B. More, Pooja P.Koshti, Shweta B. kute, & Kavita B. Argade. (2016). Identification of transformer internal faults by conventional and fuzzy three gas ratio method. International Journal Of Advance Research And Innovative Ideas In Education, 2(2), 724-730.
Chicago Vaishali B. More, Pooja P.Koshti, Shweta B. kute, and Kavita B. Argade. "Identification of transformer internal faults by conventional and fuzzy three gas ratio method." International Journal Of Advance Research And Innovative Ideas In Education 2, no. 2 (2016) : 724-730.
Oxford Vaishali B. More, Pooja P.Koshti, Shweta B. kute, and Kavita B. Argade. 'Identification of transformer internal faults by conventional and fuzzy three gas ratio method', International Journal Of Advance Research And Innovative Ideas In Education, vol. 2, no. 2, 2016, p. 724-730. Available from IJARIIE, https://ijariie.com/AdminUploadPdf/Identification_of_transformer_internal_faults_by_conventional_and_fuzzy_three_gas_ratio_method_ijariie1779.pdf (Accessed : ).
Harvard Vaishali B. More, Pooja P.Koshti, Shweta B. kute, and Kavita B. Argade. (2016) 'Identification of transformer internal faults by conventional and fuzzy three gas ratio method', International Journal Of Advance Research And Innovative Ideas In Education, 2(2), pp. 724-730IJARIIE [Online]. Available at: https://ijariie.com/AdminUploadPdf/Identification_of_transformer_internal_faults_by_conventional_and_fuzzy_three_gas_ratio_method_ijariie1779.pdf (Accessed : )
IEEE Vaishali B. More, Pooja P.Koshti, Shweta B. kute, and Kavita B. Argade, "Identification of transformer internal faults by conventional and fuzzy three gas ratio method," International Journal Of Advance Research And Innovative Ideas In Education, vol. 2, no. 2, pp. 724-730, Mar-App 2016. [Online]. Available: https://ijariie.com/AdminUploadPdf/Identification_of_transformer_internal_faults_by_conventional_and_fuzzy_three_gas_ratio_method_ijariie1779.pdf [Accessed : ].
Turabian Vaishali B. More, Pooja P.Koshti, Shweta B. kute, and Kavita B. Argade. "Identification of transformer internal faults by conventional and fuzzy three gas ratio method." International Journal Of Advance Research And Innovative Ideas In Education [Online]. volume 2 number 2 ().
Vancouver Vaishali B. More, Pooja P.Koshti, Shweta B. kute, and Kavita B. Argade. Identification of transformer internal faults by conventional and fuzzy three gas ratio method. International Journal Of Advance Research And Innovative Ideas In Education [Internet]. 2016 [Cited : ]; 2(2) : 724-730. Available from: https://ijariie.com/AdminUploadPdf/Identification_of_transformer_internal_faults_by_conventional_and_fuzzy_three_gas_ratio_method_ijariie1779.pdf
BibTex EndNote RefMan RefWorks

Number Of Downloads



Save in Google Drive

Similar-Paper

TitleArea of ResearchAuther NameAction
FLEXIBLE AC TRANSMISSION BY USING THYRISTOR SWITCHING REACTORElectrical EngineeringMr. Ashitosh A. Karape Download
SINGLE STAGE CONVERTER FOR PRECISE SPEED CONTROL OF DC MOTORElectrical EngineeringTANGELLA HARSHINI REDDY Download
Design and implementation of dual-powered charging station for Electric VehicleElectrical EngineeringMr. Kishor P. Jadhav Download
GRID CONNECTED ELECTRICAL VEHICLE CHARGING STATION WITH MULTIRENEWABLE RESOURCEElectrical and Electronics EngineeringCHANDRA SEKAR S Download
Design And Implementation of An IoT-Based Life Detector System For Accurate Human Presence Detection Under Soil During LandslidesElectrical and Electronics EngineeringDEEKSHITHA C Download
Low Cost Air Monitoring SystemElectronics and Telecommunication EngineeringShamsundar Kulkarni Download
Design and Analysis of Two Switch Boost ConverterElectrical And Electronics EngineeringDarimireddi Kiran Kumar Download
SIMULATION OF A NOVEL CLOSED LOOP CONTROL SCHEME FOR A SINGLE-SWITCH BUCK-BOOST CONVERTERElectrical and Electronics EngineeringDr. V. Sarayu Download
IOT BASED DIGITAL STARTERElectrical EngineeringShinde Sachin Download
Underground Cable Fault Detection Device Using GSM, GPS, TechnologyElectrical Power SystemMr. Nagnath V. Khandekar Download
Harmonic Voltage Control in Distributed Generation Systems Using Optimal Switching Vector StrategyElectrical and Electronics EngineeringB.Ramu Download
DESIGN & SIMULATION OF A SOLAR WIND HYBRID POWERSYSTEM USING MATLAB/SIMULINKElectronics EngineeringGARIMELLA MOHAN KRISHNA SAIRAM Download
DEVELOPMENT AND ACCEPTABILITY OF FIRE DETECTION AND ALARM SYSTEM (FDAS) TRAINERTechnology EducationNoel L. lafuente Download
ENHANCED VOLTAGE REGULATION USING A SIMPLIFIED 7-LEVEL INVERTERElectronics EngineeringKommi Manasa Download
Electricity Theft Survey In Rural AreaElectrical EngineeringTruptesh Narkhede Download
12
For Authors
  • Submit Paper
  • Processing Charges
  • Submit Payment
Archive
  • Current Issue
  • Past Issue
IJARIIE Board
  • Member Of Board
  • Join As Board
Privacy and Policy
Follow us

Contact Info
  • +91-8401209201 (India)
  • +86-15636082010 (China)
  • ijariiejournal@gmail.com
  • M-20/234 Ami Appt,
    Nr.Naranpura Tele-Exch,
    Naranpura,
    Ahemdabad-380063
    Gujarat,India.
Copyright © 2025. IJARIIE. All Rights Reserved.